PN-PT: 8.00-16.00   +48 61 864 46 00
jesteś tutaj: Merazet > Elektryczna aparatura pomiarowa > Mierniki małych rezystancji > Miliomomierz stacjonarny GOM-804 RS-232/USB/Handler

Miliomomierz stacjonarny GOM-804 RS-232/USB/Handler



Nowość
Miliomomierz stacjonarny GOM-804 RS-232/USB/Handler

Miliomomierz stacjonarny GOM-804 RS-232/USB/Handler

Producent: GW Instek

Cena netto: 2 090,00 PLN

Zamów dodaj do schowka

Opis

  • Cechy główne
    • 50,000 cyfr
    • 3.5” (320 x 240) TFT LCD wyświetlacz
    • Wysoka dokładność 0.05%
    • 1Amp prąd testu, 1µΩ rozdzielczość
    • Fast measurement of 60 readings per second
    • Four wire resistance measurement
    • Temperature compensation measurement function
    • Delayed measurement
    • 20 sets of panel setting memory
    • Dry circuit ( tylko model GOM-805)
    • Drive modes: DC+/DC-, Pulsed, PWM, Zero (GOM-805 only)
    • Interface: USB device, RS-232C, Handler/Scan/EXT I/O, and GPIB (option)

       
  • GW Instek launch a new series of D.C. milliohm meter ─ GOM-804/805, which abundantly feature 3.5-inch TFT display, maximum 50,000 counts measurement display, the rapid sampling rate of 60 readings per second, optimum 0.05% measurement precision, four wire measurement method as well as the temperature measurement and temperature compensation measurement function to meet the requirement of low resistance measurement application. The GOM-805 also includes various drive modes and Dry circuit for contact resistance measurement applications. More features, including 20 sets of panel setting memory and many external control interface such as RS-232C, USB, Handler/Scan/EXT IO or GPIB (option), greatly elevate GOM-804/805 milliohm meter’s convenience on practical applications.
     
    GOM-804/805 adopt 3.5-inch color LCD to enhance the clarity of measurement results and to provide display for related setting criteria that tremendously brings up the completeness of test information. Additionally, GOM-804/805, with the optimum 0.05% precision, augment the measurement speed to 60 sampling rate per second and maintain the display digits of five instead of four despite of different speed selections. Furthermore, the independent functionality keys and direction keys together increase the operational convenience which allows users to complete their measurement tasks with intuitive convenience and speed.
     
    GOM-805 provides Dry circuit and various drive modes (DC+, DC-, Pulsed, PWM) for measurement applications on different materials. The pulsed current output mode is suitable for interacting conductors of different materials and this output mode is to reduce the thermal EMF influence, which is caused by electric potential difference generated from different conductors acting on different temperatures while conducting low resistance measurements. The DC+ and DC- output modes are best for the measurement requirements of inductive components. The PWM output mode, ideal for changing temperature sensitive materials, can avoid resistance value variation which is due to over load happened on current measurement for a long period of time. During the DC+, DC- and Pulsed drive is supplied; the Dry circuit can work with them also. Dry circuit can limit the applied voltage under the open circuit voltage of 20mV to avoid over voltage occurred on the both ends of components. The over voltage will damage the oxide coating and the thin layer of contact surface, as a result, the validity of measurement will then be ruined. For instance, contact resistance of connector measurement is one of the applications.
     
    With respect to connecting the external control, GOM-804/805 provide a D-sub 25-pin combined interface to execute, according to the functionalities, Handler, Scan or EXT IO for respectively connecting to a sorting machine; connecting to an external on-off switch, and directly conducting external trigger control. For remote control and measurement result retrieval requirements, GOM-804/805 also provide various interface selections such as RS-232C, USB, and GPIB (GOM-804(option)/GOM-805(standard) interface. Furthermore, the control commands are compatible to that of GOM-802 that saves time in adjusting programs while switching from the old model to the new model.
     
    To sum up, GOM-804 evolves from GOM-802 platform with more advanced functionalities and specifications, including display digits, measurement speed and standard interface (RS-232C/USB). With all the capabilities of GOM-804, GOM-805 augments itself with new measurement abilities (Dry circuit and various drive modes) to meet the requirements of broader low resistance measurement applications.
 
In terms of the basic functionalities and specifications, GOM-804/805 can absolutely replace the existing model─GOM-802. All GOM-802 functionalities can be found from GOM-804/805, including resistance measurement range, 1A test current (maximum), four wire measurement method, temperature probe (option, accessory model: PT-100) for temperature measurement and temperature compensation measurement, etc. The programming commands are also compatible to that of GOM-802. To simply put it, the brand new GOM-804/805 not only provide better display interface, fast measurement (60 readings per second), but also collocate with standard communications interface (RS-232C/USB device) to facilitate users in accomplishing measurement tasks rapidly. On top of that, model switching will not be a problem.
01
GOM-804/805 has two measurement speed selections, which are Fast reaching 60 readings per second, and Slow 10 readings per second. A major departure from the past, users, in the past, had to juggle between speed and display resolution. GOM-804/805 will not affect resolution despite of any speed selections and will maintain the highest display digits. In other words, reading resolution will not be changed by changing speed and the display digits remain the same.
02
  • Dry circuit is to limit test voltage and current to certain levels which will not cause contact points to produce physically or electrically changed circuit and its most frequently used application is contact resistance of connector measurement. Based upon MIL-STD-1344 method 3002-1 low signal level contact resistance, tests must be applied under the maximum open circuit voltage of 20mV (or lower), and short circuit current of 100mA (or lower) to avoid over voltage for the both ends of components. The over voltage will damage the oxide coating and the thin layer of contact surface, as a result, the validity of measurement will then be ruined. GOM-805 provides three levels (500mΩ:100mA/5Ω:10mA/50Ω:1mA) to limit open circuit voltage at 20mV to execute Dry circuit tests.
    03
     
    GOM-805 provides various current output drive modes to satisfy diversified and accurate low resistance measurement applications. For instance, for interacting conductors of different materials, the pulsed current output mode can be applied to reduce the thermal EMF influence, which is caused by different conductors acting on different temperatures. The PWM output mode, ideal for changing temperature sensitive materials, can avoid resistance value variation which is due to over load on large current measurement in a long period of time. The DC+ and DC- output modes are best for the measurement requirements of inductive components.
    04
With respect to connecting the external control, GOM-804/805 provide a D-sub 25-pin composite interface to execute, according to the functionalities, Handler, Scan or EXT IO for connecting to a sorting machine; connecting to an external on-off switch, and directly conducting external trigger control respectively. For remote control and measurement result retrieval requirements, GOM-804/805 also provide various interface selections such as RS-232C, USB, and GPIB (GOM-804(option)/GOM-805(standard) interface.
05
  • The commands of GOM-804/805 are compatible to that of GOM-802 that allows users to switch equipment with simple settings. There is no cost in adjusting existing programs and production delay will not be happening while switching from the old model to the new model.


Specyfikacja

  • General

    NOTE

    Specifications are ensured only for GOM-804/805 at least 30 minute of warm-up time and Operating Temperature Specification: 18~28˚C

    Display

    3.5'(320 x 240) TFT LCD

    Memory

    20 sets for panel setting

    Power Source

    AC 100 - 240 V, 50/60Hz

    Comsumption

    25VA (max.)

    Dimension

    223(W) x 102(H) x 283(D) mm

    Weight

    Approx.3kg(max.)

     

    Specifications

    MODEL

    GOM-804

    GOM-805

    DISPLAY

     

    50,000 counts

    SAMPLING RATE

    Slow

    10 readings / s

    Fast

    60 readings / s

    RESISTANCE MEASUREMENT

    Range / Test current (fixed)

     

    50mΩ /1A

    500mΩ / 100mA

    5Ω / 10mA

    50Ω / 1mA

    500Ω / 1mA

    5kΩ / 1mA

    50kΩ / 100µA

    500kΩ / 10µA

    5MΩ / 1µA

     

    Accuracy

    50mΩ : ± (0.1% of reading + 0.02% of range)

     

    500mΩ ~ 50Ω : ± (0.05% of reading + 0.02% of range)

     

    500Ω ~ 500kΩ : ± (0.05% of reading + 0.008% of range)

     

    5MΩ : ± (0.2% of reading + 0.008% of range)

    Resolution

    1µΩ, 10µΩ, 100µΩ, 1mΩ, 10mΩ, 100mΩ, 1Ω, 10Ω, 100Ω

    TEMPERATURE

    Range

    -50˚C ~399.9˚C

    Accuracy

    -10˚C ~40˚C : 0.3% ± 0.5˚C ; Other : 0.3% ± 1.0˚C

    Resolution

    0.1˚C

    DRY CIRCUIT

     

    -----

    Open circuit less than 20mV;

    For 500mΩ, 5Ω, 50Ω range only

    DRIVE MODE

    DC+/DC-

    -----

    Yes

    Pulsed

    -----

    Yes

    PWM

    -----

    Yes

    Zero

    -----

    Yes

    OTHER FUNCTIONS

     

    Trigger – Internal, Manual, External、Math – ABS, REL, %, TC、Hi / Lo

     

    Average 2 ~ 10 times、Measured delay、Go / No-Go、TC for Transformer

     

    Diode、Continuity beeper、Sorting (only for GOM-805)

    INTERFACE

    USB

    Standard

    Standard

    RS-232C

    Standard

    Standard

    HANDLER/SCAN/EXT I/O

    Standard

    Standard

    GPIB

    Option

    Standard

 



Dodatkowe informacje

  • Accessories

    Quick Start Guide x 1, Power cord x 1, Test lead GTL-308 x 1, CD x1(complete user manual)

     

    Option

    Opt. 1 GPIB card (only for GOM-804 and must be installed at factory before shipment.)

     

    Optional Accessories

    PT-100     Platinum Temperature Probe
    GTL-232   RS-232Ccable 9-pin, F-F type, approx.2000mm
    GTL-248   GPIB cable approx.2000mm
    GTL-251   GPIB-USB-HS (High Speed) adaptor


Kontakt z handlowcem
Szymon Białkowski
szymon.bialkowski@merazet.pl

tel. +48 61 8644 610
kom. +48 698 676 958


Formularz zapytania
Formularz zostanie wysłany do handlowca odpowiedzialnego za produkt


Komentarze o produkcie


1
Kontakt
 
MERAZET Spółka Akcyjna
ul. J.Krauthofera 36,
60-203 Poznań

 

tel. +48 61 8644 600,

fax: +48 61 8651 933

 

e-mail: poczta@merazet.pl

 

katalog produktów Zamów

Zapraszamy do zapoznania się z aktualnymi katalogami naszych produktów.

Newsletter

Korzystanie z witryny oznacza zgodę na wykorzystanie plików cookie z których niektóre mogą być już zapisane w folderze przeglądarki.
Więcej informacji można znaleźć w Polityce prywatności i wykorzystywania plików cookies w serwisie

Akceptuję politykę prywatności i wykorzystywania plików cookies w serwisie